Technical Data of CFB Biomass Steam Boiler | ||||||||
Model | Rated Evaporation Capacity (t/h) | Rated Steam Pressure (MPa) | Feed Water Temperature (°C) | Rated Steam Temperature (°C) | Fuel Consumption (kg/h) | Primary Air Fan | Secondary Air Fan | Induced Air Fan |
TG35-3.82-SW | 35 | 3.82 | 150 | 450 | 8680 | Q=30911m3/h P=14007Pa | Q=25533m3/h P=8855Pa | Q=107863m3/h P=5200Pa |
TG75-3.82-SW | 75 | 3.82 | 150 | 450 | 18400 | Q=52500m3/h P=15000Pa | Q=34000m3/h P=9850Pa | Q=200000m3/h P=5500Pa |
TG75-5.29-SW | 75 | 5.29 | 150 | 485 | 18800 | Q=52500m3/h P=15000Pa | Q=34000m3/h P=9850Pa | Q=200000m3/h P=5500Pa |
TG75-9.8-SW | 75 | 9.8 | 215 | 540 | 19100 | Q=52500m3/h P=15000Pa | Q=34000m3/h P=9850Pa | Q=200000m3/h P=5500Pa |
TG130-3.82-SW | 130 | 3.82 | 150 | 450 | 29380 | Q=91100m3/h P=16294Pa | Q=59000m3/h P=9850Pa | Q=2x152000m3/h P=5500Pa |
TG130-5.29-SW | 130 | 5.29 | 150 | 485 | 29410 | Q=91100m3/h P=16294Pa | Q=59000m3/h P=9850Pa | Q=2x152000m3/h P=5500Pa |
TG130-9.8-SW | 130 | 9.8 | 215 | 540 | 29500 | Q=91100m3/h P=16294Pa | Q=59000m3/h P=9850Pa | Q=2x152000m3/h P=5500Pa |
Remark | 1. Design efficiency is 88%. |