Technical Data of SHW Biomass Steam Boiler | |||||||||
Model | Rated Evaporation Capacity (t/h) | Rated Steam Pressure (MPa) | Feed Water Temperature (°C) | Rated Steam Temperature (°C) | Radiation Heating Area (m2) | Convection Heating Area (m2) | Economizer Heating Area (m2) | Air Preheater Heating Area (m2) | Active Grate Area (m2) |
SHW6-2.5-400-SW | 6 | 2.5 | 105 | 400 | 14.8 | 110.4 | 163.5 | 98 | 8.5 |
SHW10-2.5-400-SW | 10 | 2.5 | 105 | 400 | 42 | 272 | 94.4 | 170 | 12 |
SHW15-2.5-400-SW | 15 | 2.5 | 105 | 400 | 62.65 | 230.3 | 236 | 156.35 | 18 |
SHW20-2.5/400-SW | 20 | 2.5 | 105 | 400 | 70.08 | 490 | 268 | 365.98 | 22.5 |
SHW35-3.82/450-SW | 35 | 3.82 | 105 | 450 | 135.3 | 653.3 | 273.8 | 374.9 | 34.5 |
SHW40-3.82/450-SW | 40 | 3.82 | 105 | 450 | 150.7 | 736.1 | 253.8 | 243.7 | 35 |
SHW45-3.82/450-SW | 40 | 3.82 | 105 | 450 | 139.3 | 862.2 | 253.8 | 374.9 | 40.2 |
SHW75-3.82/450-SW | 75 | 3.82 | 105 | 450 | 309.7 | 911.7 | 639.7 | 1327.7 | 68.4 |
Remark | 1. Design thermal efficiency is 82%. |